Hi Silvia, here is a short list of the changes that were performed: ID Description Details INT_DCR-29 Insert Upper & Lower Limit on IREM output (U9919, U9920) Low limit 0 / High limit 65534 INT_DCR-30 Change Calibration for TC parameters E8979/F8979 (PAFREF 6404) New IASW (v435) with PSD Event compression functionality (OCR-261) INT_DCR-31 Change Calibration for TM parameters E3979/F3979 (TXF_NUMBR 6404) New IASW (v435) with PSD Event compression functionality (OCR-261) INT_DCR-33 New SPI EDs EENTRY03 and EEXIT-03 New version of SPI IASW (435) which reduces the GeD HV during the radiation belts INT_DCR-34 Updated sequence ES0071 Corrected relative timing of commands INT_DCR-32 New monitoring checks for SPI GeD HV setting in radiation belts New IASW (v435) which changes the setting of the Ge detector high voltages during the radiation belts Please let me know if you need more detailed information. Regards, Stefano De Padova Integral & XMM-Newton Analyst European Space Operations Centre, OPS-OAI Phone: +49-6151-90-2143 Email: Stefano.De.Padova@esa.int Serco European Agencies Robert-Bosch-Strasse 7 64293 Darmstadt Germany