INTEGRAL LOGO Key performance parameters of the Optical Monitor OMC


Parameter   Value 
Wavelength range  500 - 600 nm  (Johnson V-filter)
Detector 50 mm lens + CCD (2055 x 1056 pixels),
imaging area = 1024 x 1024 pixels
Pixel size (13 x 13) micrometer^2
= (17.5 x 17.5) arcsec^2
Field of view 5 x 5 deg
Angular resolution 23"
Typical integration times 10 s - 50 s - 200 s
Sensitivity
(3 sigma in 10 x 200 s)
18.1 mag (v)
Photometric accuracy  < 0.3 mag for < 16 mag and > 300 s
Typical source location accuracy 6"